塔吊接地
![塔吊避雷接地](https://imgs.wantubizhi.com/img/A1A61BAA66193547F3A6DD7D8EE527E97F8D30B8C72D3417E6C42CBCD22AB0256C405E7629BC2D07EDC5F5E88A9EE6384C65D90A44C9465BB29ECDB4926A3F29DF7232E69EF98EA04528F7590A847E03FA2F1C505A3D6F75BA0EE4BAA2BBBB1A)
塔吊避雷接地
图片尺寸1200x1600![1.塔吊防雷接地一处因施工损坏,未及时修复.](https://imgs.wantubizhi.com/img/A1A61BAA66193547F3A6DD7D8EE527E9CB6BCE2010AEF14574FF9991D430249BC53FBCB0C5435D71663946AE7033D969F15BA187F6F1232DDB74D981B93EC1D0C78E4A60E6DEEE30C05D238273AF22E9B30700FA13DDEAC1BCA20B5FF5F561C3)
1.塔吊防雷接地一处因施工损坏,未及时修复.
图片尺寸2667x2000![塔吊防雷接地的焊接](https://imgs.wantubizhi.com/img/735A5D1F980B52A636CC46F12F2D1A734A419AEF574F60092F9CF310F9780D86065DA7DF902F0839F24EE0AE71D57C9E888207172516B1B97E6A0855EE5B3330826AE21246EEDB204A610931D4BF1E5C20F9EE8633846431B2E967D4C336BD04)
塔吊防雷接地的焊接
图片尺寸2000x3556![海沧保障性住房a4地块4号塔吊安装监控记录](https://imgs.wantubizhi.com/img/735A5D1F980B52A636CC46F12F2D1A73FC6118D69E52D7E833DF838D51FC1AD6BB1F2D421E477C284AFBBF580E6AF795B370F2F7893AF45BEA89E546DAB3687E358D7FBE0E23B2A518CF8A42BA12A590B0C32B2B074F41D4052E3AC257988F56)
海沧保障性住房a4地块4号塔吊安装监控记录
图片尺寸1200x2133![塔吊防雷接地如何施工?](https://imgs.wantubizhi.com/img/A1A61BAA66193547F3A6DD7D8EE527E96D67F5A3C2BDA75BAC6D60BCCA2DE6EEBACFA20C5BC07FA34D4B158BB9D281244283FB0CE67932A7DDC8350F47EAA49DB920BCBF77EF2A5DC6E10A114EB85B032281983AA8DCD1D13BAC6C9995EB2034)
塔吊防雷接地如何施工?
图片尺寸640x480![a4地块1,2号塔吊整改效果](https://imgs.wantubizhi.com/img/735A5D1F980B52A636CC46F12F2D1A73E2FC278A6B1BFD8AF297F4B5DF310644534FF2F2AA5551003AABEB7D781A46FC67FD18678352DFCE73B8521A08B428750FAACA4C3DC00E293E5FEE06FCF0F046934851431E5848790B5C5CB5A048B389)
a4地块1,2号塔吊整改效果
图片尺寸2133x1200![监理怎么查塔吊安全重点总结](https://imgs.wantubizhi.com/img/A1A61BAA66193547F3A6DD7D8EE527E9AD8AE9D32C650056032CDA198A51BB84EC1078FF8C1747074A319A05669B0A13524F4C363782AB443A86F7D4CDE2E7FC36D630D404A6A36F22C5D354EC7BCBDEBF76063CD1F0C3DD98116C883E715357)
监理怎么查塔吊安全重点总结
图片尺寸748x494![配电箱的接地线能直接接地塔吊的接地体吗](https://imgs.wantubizhi.com/img/A1A61BAA66193547F3A6DD7D8EE527E943A0FB6E55B1AE0601836259838F93DA30837746113F209AB2355C8675A6E902205E291CB4AB5241404D5149845E6C42EA00376B6BF9EA164DB490D3C1800D644BDD6474F063302C7E453F353E0B3042)
配电箱的接地线能直接接地塔吊的接地体吗
图片尺寸760x1353![重复接地系统,并安装一组3根接地极,其中接地极距离塔吊接地点≥5m,3](https://imgs.wantubizhi.com/img/ADDA3C5D760C6828B77B505A29D43E83D4A02D3F2F45C6013E61BC214BC4CDBE2CD8340DA61E80E103B7F60D493F97F3493776D9D47B0F1C7FFE09992B4A2AE4926C1A418D1A14A817B8AAAEF8FB19C6029435C0FD0053C38182372801833AB9)
重复接地系统,并安装一组3根接地极,其中接地极距离塔吊接地点≥5m,3
图片尺寸410x244![2 基础检查常见问题, 地脚螺丝预埋方法不规范, 防雷接地做得不规范](https://imgs.wantubizhi.com/img/A1A61BAA66193547F3A6DD7D8EE527E99F6807FD8AC7EC4D24637125A4FB31144A1952AAD30AF58F1BCBCDE5CCAD32680EE61B20692A486A77635923C3D73474451680CCF7A7FC69D9F3D96CEBD44F8E93FFADA491F5210058855D8C3E450F2F)
2 基础检查常见问题, 地脚螺丝预埋方法不规范, 防雷接地做得不规范
图片尺寸661x432![塔吊基础防雷接地做法](https://imgs.wantubizhi.com/img/ADDA3C5D760C6828B77B505A29D43E832DC266A46DACABF372EA973A5AF66749CB7ADBDA09C8A7B4AF7C2600DB1CF27BA10F0AA27495E6097197F2FED690FB7D7ADA741BC48BCE11C48DF6070BAB996A50C30932658702805FBCD1746DCBFF48)
塔吊基础防雷接地做法
图片尺寸480x270![现场塔吊防雷接地做法错误,须取三个点砸钎子,用扁铁连接,引出基础二](https://imgs.wantubizhi.com/img/735A5D1F980B52A636CC46F12F2D1A73316852D3B50E9504678DCDAF7141D7B0F8130E5131044DD0915709028DDC34481932F7D1618B0994253C8096010F87D3FE4407A616670A59FC8B3A57EE0C63A476D2C7E923748C79E889F69249213A46)
现场塔吊防雷接地做法错误,须取三个点砸钎子,用扁铁连接,引出基础二
图片尺寸1200x2133![塔吊防雷接地如何施工?](https://imgs.wantubizhi.com/img/735A5D1F980B52A636CC46F12F2D1A73F02999EF120AD090A9ACA8C51CE0AB31F317B2FCE3D915991429F687AEF277F3233E613DC900D14A67BD2A750135F2150D1A2340FEA2DF59B936190CFED9F7CB5401CEA16C4C8AF519FC8DFAC802959A)
塔吊防雷接地如何施工?
图片尺寸2000x1127![4,施工现场塔吊接地线相线不匹配.](https://imgs.wantubizhi.com/img/ADDA3C5D760C6828B77B505A29D43E8333202F2043065A859773D9F0AB56D8D931BC9F7E33BA6C6C506BFC439AC69F438B63B7B9E3862055261D23DFC63DD00E5136E002558423CE3BA7F6F0EAD3C72F2668D5882D23413C00AAE6106001F7D6)
4,施工现场塔吊接地线相线不匹配.
图片尺寸2000x2667![塔吊接地注意哪些问题?需要重复接地吗?怎么接?](https://imgs.wantubizhi.com/img/735A5D1F980B52A636CC46F12F2D1A73234D1926E5ABCC17BD49B51D605988AEC7B09DBECCB94A1731DD738FC7F631B594A2671C2AA8824BE858F0666329F56AF47255BD401AD813888A99C1CC63E60E5B6998DBAE5AEA07649DC1791D3418B8)
塔吊接地注意哪些问题?需要重复接地吗?怎么接?
图片尺寸560x996![塔吊防雷接地如何施工?](https://imgs.wantubizhi.com/img/A1A61BAA66193547F3A6DD7D8EE527E9EADECEBF3CBACC52551460432394217C4BBAD051C0721CDD6C93B79B5559DCAA8B45DD7CAA8D9356C6D17C5B718E5982C4406BB6AF70CD636FEA4692BBADA4E11D541DF2B390BA6526AFA56ACFF87820)
塔吊防雷接地如何施工?
图片尺寸640x360![塔吊,脚手架防雷接地▲配电箱接地设施4,漏电保护器电工应每日检查](https://imgs.wantubizhi.com/img/A1A61BAA66193547F3A6DD7D8EE527E9BC30F6D0D384E8A36773C06FF0B00E3D5F22D2529B1BC4C601D0EAC567F2B166FEE431B3E7C81CCB6B0D0CCD33AA153FAF4E2F7F9DD836835CF3680F0B353B0BABFD6F8EC7647499F7AFDB80BBBED47B)
塔吊,脚手架防雷接地▲配电箱接地设施4,漏电保护器电工应每日检查
图片尺寸1080x606![海沧a4地块2号塔吊:防雷接地的焊接.](https://imgs.wantubizhi.com/img/735A5D1F980B52A636CC46F12F2D1A7399758254ABA4715464A9B9335D6FB271BC761ED2AC4DEB14C436B0E3630C374813F52FDC21E522E30304D356AE2856C3F8C3C516278465E2CEE9A49FA6C6E6F961553046B79E9AE84FC19A7C2B905D3E)
海沧a4地块2号塔吊:防雷接地的焊接.
图片尺寸2000x3556![大工匠丨思达·汇金天地,让你一铺"盈"天下](https://imgs.wantubizhi.com/img/735A5D1F980B52A636CC46F12F2D1A73177C910CAD286C90B10B67BC0C96A60744DE0750431A83FE551E5A98FF2D84BC08DAF802E9262071B7B68B07DB10CA2B221028548E112DCB2800F400807A5CE1BF59CD4BB176CB9F18D5F4FA9F312F64)
大工匠丨思达·汇金天地,让你一铺"盈"天下
图片尺寸960x720![随意将保护接零线捆在一铁丝上作为重复接地.](https://imgs.wantubizhi.com/img/ADDA3C5D760C6828B77B505A29D43E83C347CE4ACF7C77374845A2A32C14650B360AA394E1C888F135DF81D58B9B17F019F37AD618069F17B04BF6F7912C2ACB16D55E32F62102F07AFBD9915BDC7E72E1B0E1F1E4179A224A68CCA16A0393B1)
随意将保护接零线捆在一铁丝上作为重复接地.
图片尺寸560x388